66RNS1011251213  - Inor Slovenia  Sales

BRAND Inor
Product 66RNS1011251213
Description Sensor
Internal code IMP156444
Weight 0.3
Custom code 90251900
Technical specification TRA-S11 NOR Threaded resistance thermometer Type OPTITEMP TRA-S 11 Connector head BA - Material Aluminium - Cable gland M20 x 1.5 - Degree of protection IP65 - Connection M24 x 1.5 Measure insert ME Mi, replaceable, sprung - Sensor type 1xPT100-A-3-TF-Ø6 Thin film according to DIN EN 60751 - Circuit type 3-wire - Tolerance Class A - temperature range -50... +300°C - Material Stainless steel - Connection type ME with clamping base Protective tube multipled/welded - Diameter 10 x 1 mm - Tip cylindrical - Installation length U1 see DESIGN DATA - Process connection G 1/2 A - Material 1.4404/316L (TC 600°C) http://krohne-inor.se/laddaner/dokumentation/ DESIGN DATA Installation length: 510 mm Neck tube length: 0 mm Customer ID 66RNS1011251213 VTS14201223210Z0100000000000000

Please Contact Us to Order to offer competitive prices and delivery time for Inor - 66RNS1011251213 Sensor number, also you may ask some other model number is well. We can offer competitive price, and delivery time with wide products distribution network in Slovenia Industrial products Market. 

WE SELL ONLY NEW AND ORIGINAL PRODUCTS!

Our company is not an authorized distributor. All rights are reserved by the manufacturers and their official partners.

More products of Inor

70IPL00001

PC programmable two-wire transmitter for DIN rail mounting;Inp. / Outp. galvanically isolated 1,5 kV, 11 T / C, Pt100 ... Pt1000; Ni100/Ni1000, 3 -or 4-wire connection; 4-20/20-4 mA output, linear with temperature;Factory setting: Pt100, 3L, 0 ... 600 ° C, weight: approx. 40gIncluding: 70CAL00001 - Programming / Configuration:Pt100, 4-wire connection; -20 ... +160 ° C, 4 ... 20 mA

70IPL00001 / IPAQ-L

PC-programmable two-wire transmitter for DIN rail mounting

APAQ - L

The temperature transimitter

APAQ-LC

70APLC0001 APAQ-LC Analog Adjustable Two-Wire Transmitter for thermocouple input and 4... 20 mA output DIN Rail Mounting uncalibrated

PT100-IPAQ-L/70- I-PL00001. N11137.554587.V0571005521.

ORDER: 49,499,237. 3-L; -20..100 DEGREES

RAG±50/2000-M

Vishay Displacement transducer Input voltage 3Vrms Linear range: 0- 100mm

STC1920ABA3530Z0000000000000 - OPTITEMP TCA-P 62 SPECIAL

(THERMOMETER *** Only Thermowell *** Type: *** OPTITEMP TCA-P 62 Special ***, Protection Tube: 1.4762 Chrome Steel - diameter: Æ 22x2,0 mm - tip design: Straight tip design Process connection: Compression Fitting G1"; 1.4404 (300 °C) Acessories: *** Stop ring ***, APPLICATION DATA Immersion Length: 1200 mm Extension Tube: 0 mm STC1920ABA3530Z0000000000000)

STC1920ABA3530Z0000000000000 - OPTITEMP TCA-P 62 SPECIAL , 1020 MM, 0MM

(THERMOMETER *** Only Thermowell *** Type: *** OPTITEMP TCA-P 62 Special ***, Protection Tube: 1.4762 Chrome Steel - diameter: Æ 22x2,0 mm - tip design: Straight tip design Process connection: Compression Fitting G1"; 1.4404 (300 °C) Acessories: *** Stop ring ***, APPLICATION DATA Immersion Length: 1020 mm Extension Tube: 0 mm STC1920ABA3530Z0000000000000)

STC1920ABA3530Z0701000000000 - OPTITEMP TCA-P 62 SPECIAL

(Connection head: AA, aluminium; Cable gland M20x1,5; Protection class IP54 Measuring insert: Mii, replaceable, spring-loaded;1x Type K (NiCr-Ni); Sensor cass 1, Temp. range type K max 1150 °C; Inconel 600 Protection tube: 1.4762 Chrome Steel - diameter: Æ 22x2,0 mm - tip design: Straight tip design Process connection: Compression Fitting G1"; 14404(300 °C) Acessories: *** Stop ring *** Immersion Length: See Application Data Connection head mount transmitter; two-wire universal transmitter - type: TT30C / - design: head mounted / - input: RTD/Thermocouple - galvanical separation: 1500 VAC, 1 min Private Label: KROHNE Standard Version,APPLICATION DATA Immersion Length: 1200 mm Extension Tube: 0 mm STC1920ABA3530Z0701000000000)

STC1920ABA3530Z0701000000000 - OPTITEMP TCA-P 62 SPECIAL, 1020 MM

(THERMOMETER Plug-In Thermocouple Type: ''' OPTITEMP TCA-P 62 Special ***, Connection head: AA, aluminium; Cable gland M20x1,5; Protection class IP54 Measuring insert: Mii, replaceable, spring-loaded;1x Type K (NiCr-Ni); Sensor cass 1, Temp. range type K max 1150 °C; Inconel 600 Protection tube: 1.4762 Chrome Steel - diameter: Æ 22x2,0 mm - tip design: Straight tip design Process connection: Compression Fitting G1"; 14404(300 °C) Acessories: *** Stop ring *** Immersion Length: See Application Data Connection head mount transmitter; two-wire universal transmitter - type: TT30C / - design: head mounted / - input: RTD/Thermocouple - galvanical separation: 1500 VAC, 1 min Private Label: KROHNE Standard Version, APPLICATION DATA Immersion Length: 1020 mm Extension Tube: 0 mm STC1920ABA3530Z0701000000000)

70ISP32 X Y Z

Isolationssignal-Splitter mit doppelten Ausgängen für mA/V Signale

P/N: 70IP4L0001 Type: IPAQ-4L

PC Programmable Four-wire Transmitter

70IPHX0001 / IPAQ-HX

PC programmable two-wire transmitter

66RKS0611212103

Temperature sensor

P/N: 70APHRF001 Type: APAQ-HRF

Analog Adjustable 2-wire Transmitter

Order No. 70APHCF001, Type: APAQ-HCF

Analog Adjustable 2-wire Transmitter

Order No. 70C2010010, Type: IPAQ C201

Analog PC-Programmable 2-wire Transmitter for Pt100 Input

p/n: 70MQHLP002, Type: MinIPAQ-HLP

insulated two-wire transmitter

P/N: 70IPHP0001, Type: IPAQ-HPLUS

High-precision Universal Programmable 2-wire Transmitter

70MEH00001

Transmitter

Order No. 70C5200010, Type: IPAQ C520

HART Compatible, Universal, Dual-input 2-wire Transmitter

Other Category Brands

Contact us for request