4951  - Isotech Slovenia  Sales

BRAND Isotech
Product 4951
Description ISOCAL - 6 Range
Internal code IMP4005288
Technical specification Product Highlights -45°C to 250°C. 35 x 160mm Volume Fast Response 35mm x 160mm Calibration Volume Calibrate Whole Measurement Loop Stability ±0.03°C Stability Blackbody ±0.03°C Surface Sensor ±0.5°C ITS-90 Cells ±0.0005°C Uniformity - Between Wells Dry Block Mode (Radial)Uniformity - Lower 40mm (Axial) Dry Block ModeUniformity - Radial Bath ModeUniformity - Lower 40mm (Axial) as Liquid BathHeating Time -30°C to 140°C: 15 mins Cooling Time 140°C to 0°C: 15 mins Calibration Volume 35 x 160mm Standard Insert 6 pockets, 2 x 4.5mm, 2 x 6.4mm, 1 x 8.0mm, 1 x 9.5mm diameter, all 157mm deep Insert Types Choice of three - See Accessories CJC Accuracy 0.35°C Dimensions 384H (including handle) x 212W x 312D mm Power 150 Watts Voltage 115Vac or 230Vac 50/60Hz 1 In ambient of 20°C: Min. Temperature is 65°C Below Ambient, Absolute Minimum -55°C 2 In ambient of 20°C: Min. Temperature is 55°C Below Ambient, Absolute Minimum -45°C 3 In ambient of 20°C 4 Dry Block Mode only: Comparing 4.5mm Well to Controller Display Value

Please Contact Us to Order to offer competitive prices and delivery time for Isotech - 4951 ISOCAL - 6 Range number, also you may ask some other model number is well. We can offer competitive price, and delivery time with wide products distribution network in Slovenia Industrial products Market. 

WE SELL ONLY NEW AND ORIGINAL PRODUCTS!

Our company is not an authorized distributor. All rights are reserved by the manufacturers and their official partners.

More products of Isotech

006-A

Lbaboratory Decade Rrsistance box for RTD Simulation

935-14-61/DB

(Working standard platinum resistance thermometer, Model Isotech 935-14-61 Pt100 DIN IEC 751 (1/10 DIN) as described in the data sheet Ro: 100 ohms ± 0.05 ohms, Alpha: 0.003850 ± 0.000005 Stability: 0.010 ohms / year Temperature range: -50 ° C to 250 ° C Length: 300 mm Diameter: 4 mm)

935-14-91-R-300

Thermoelement

935-14-95H/TTI

Semi-Standard Platinum Resistance Thermometer

935-14-95H

platinum resistance thermometers

C10-OL 1L

(Thermal oil C10 Silicon oil (-35 ° C to 140 ° C) 1 liter )

EUROPA S ONSITE-VERSION

Temperature Range -45°C to +140°C Reference Pt100 Model 935-14-82/DB Stability ± 0,03°C Insert 951-06-07 Liquid Container 951-06-01 Liquid in Glass Thermometer Support Kit 951-06-03 C10 Silicon Oil (-35°C to 140°C) 520-05-01 Software and connecting cable 220V/ 50HZ

IPS 3610D

power supply

ISOTECH ISIS

Dry Block Calibrator Jupiter

ISOTECH JUPITER B PLUS

Small calibration system, temperature range: +35°C to 650°C

ISOTECH JUPITER SN PLUS

Dry Block Calibrator Jupiter

ISOTECH PEGASUS PLUS SN 1200

High Temperature-Blockcalibrator

Jupiter S 650 Vor-Ort-Version

calibration system

KLEINKALIBRIERANLAGE ISOTECH HYPERION 2140 B MODELL 936

Model 936 as the basic version without reference thermometer for calibrating thermocouples in the temperature range of -45 ° C (-45 ° C under Ambient temperature) to + 140 ° C Calibration 65mm at 160mm immersion depth calibration depth 160mm absolute stability of ± 0.03 over 30 minutes Measurement uncertainty of up to ± 0.1 ° C otherwise after techn. Description in Datasheet incl. a traceable works certificate with RS 232 interface for setting and reading out display and controller with software CalNotePad Dimensions and weight see data sheet 220V / 50HZ Scope of supply: Hyperion, thermometer holder, magnetic stirrer, Cover, serial cable and Cal Notepad software Note: eXacal compatible

KLEINKALIBRIERANLAGE TYP ISOTECH ISIS

includes standard insert and insulating plug, serial communications and cal notepad Software and Traceable certificate, temp Range: -100'c to 40 'c

KLEINKALIBRIERANLAGE TYP ISOTECH JUPITER B PLUS

Dry Block Calibraincludes standard insert , 3 point traceable certificate , serial communications and cal notepad temp reng: 35 'c to 650 'c basic version tor

M210.

Milliohm meter

Artikel Nr.: 923

milliK Präzisionsthermometer

MODELL ISOTECH NEPTUN 915 H

30 ° C to 300 ° C Uncertainty: absolute ± 0.0005 ° C (with FP-cells)   vertical ± 0.003 ° C   ± 0.001 ° C in the vicinity of the   ambient temperature   to ± 0.001 ° C when compared calibration Liquid quantity: 7 liters Workspace: 100mm   400mm deep incl. RS 232 interface 240V - 50 Hz Further description gem. data sheet   

Other Category Brands

Contact us for request